- Siberian Journal of Physics
- Archive
- 2009
- Vol 4. No 2
- Quantum Optics, Quantum Electronics
CALCULATION OF THE X-RAY HOLOGRAPHIC LENS FOR THE NANOMETRIC RANGE OF SPECTRUM
Yuriy Ts. Batomunkuev
1. Optics and Optical Technologies Institute, Siberian State University of Geosystems and Technology, Novosibirsk, Russia
opttechnic@mail.ru
Nikolay A. Mescheryakov
1. Optics and Optical Technologies Institute, Siberian State University of Geosystems and Technology, Novosibirsk, Russia
The material was received by the Editorial Board: 11.01.2009
Calculation of x-ray holographic lenses with corrective spherical aberration of the seventh order for working wavelength 2,4 nm, 4,5 nm and 13,5 nm is executed in article. The radius of surfaces of holographic lenses is determined from condition of maximum of diffractive efficiency. It is shown that consideration of shrinkage of thickness of the holographic lenses allows to correct the spherical aberration of the fifth order. It is obtained that holographic lenses with greatly different working wavelengths can be recorded on one scheme by choice of optimum of wavelength of coherent source. The relative diameters of the obtained holographic lenses are 1:1,1, 1:1 and 1:0,9. Keywords:
x-ray optics, holographic lens, aberrations of x-ray hologram.
УДК 535.417
CALCULATION OF THE X-RAY HOLOGRAPHIC LENS FOR THE NANOMETRIC RANGE OF SPECTRUM
References: Batomunkuev Yu.Ts., Mescheryakov N.A. CALCULATION OF THE X-RAY HOLOGRAPHIC LENS FOR THE NANOMETRIC RANGE OF SPECTRUM. Vestnik NSU. Series: Physics. 2009, vol. 4, no. 2. P. 3–7 (in Russ.). DOI: 10.54362/1818-7919-2009-4-2-3-7