ALTERNATIVE TECHNIQUE OF INVERTER POWER SOURCE SYNCHRONIZATION

Petr A. Bak
1. Budker Institute of Nuclear Physics SB RAS Novosibirsk, Russian Federation
P.A.Bak@inp.nsk.su
Andrey V. Ottmar
1. Budker Institute of Nuclear Physics SB RAS Novosibirsk, Russian Federation
aottmar@gmail.com
Dmitriy A. Starostenko
1. Budker Institute of Nuclear Physics SB RAS Novosibirsk, Russian Federation
The material was received by the Editorial Board: 10.04.2014
In devices synchronized with electric mains and sensitive to interference (particularly to an inverter power source) it is expedient to also synchronize the power source. The paper describes a method of synchronizing the inverter power supply with the mains. The general aspects of the method are discussed in detail, and possible hardware implementations are considered. External factors and internal parameters affecting the quality of synchronization are analyzed. The results of practical implementation of this method for synchronization of klystron filament power supply are presented.

Keywords:
power supply, synchronization with electric mains, klystron filament, phase shift modulation, interference suppression. 
УДК 539.1.076

ALTERNATIVE TECHNIQUE OF INVERTER POWER SOURCE SYNCHRONIZATION
References: Bak P. A., Ottmar A. V., Starostenko D. A. ALTERNATIVE TECHNIQUE OF INVERTER POWER SOURCE SYNCHRONIZATION. Vestnik NSU. Series: Physics. 2014, vol. 9, no. 3. P. 20–24 (in Russ.). DOI: 10.54362/1818-7919-2014-9-3-20-24